Noch Fragen? 0800 / 33 82 637

Usefulness of acute phase proteins and simplified Light´s criteria in identifying aetiology of body cavity effusions in cats

Produktform: Buch / Einband - flex.(Paperback)

Cats with body cavity effusions are commonly presented to veterinary practices. They might suffer from a variety of conditions, including heart disease, neoplasia, septic process, or feline infectious peritonitis (FIP). Timely diagnosis is essential to institute appropriate treatment. This thesis was designed with the aim to assess the utility of acute phase proteins (APPs) (measured in serum and effusion) to differentiate FIP from other diseases causing body cavity effusions, and to evaluate the ability of different classification schemes and APPs (measured in serum and effusion) to differentiate between exudative and transudative effusions. Eighty-eight cats with body cavity effusions were included in the assessment of utility of APPs in diagnosing FIP, and 65 cats were included in the study evaluating the ability of different classification schemes and APPs to differentiate between exudative and transudative effusions. Of the 88 cats, 44 had pleural effusion, 37 had ascites, five had both ascites and pleural effusion, and two had pericardial effusion. Of the 88 cats, 24 had a tumour, 22 had a cardiac disease, 20 had FIP and 22 were diagnosed with other diseases (mainly septic conditions). Analysis of effusion included total nucleated cell count (TNCC), total protein (TP), albumin, activity of lactate dehydrogenase in effusion (LDHef), and cytological examination. Simplified Light’s criteria (LDHef, effusion/serum TP [TPr]) and serum-effusion albumin gradient (ALBg) were available in 65 cats. Acute phase proteins serum amyloid A (SAA), α1-acid glycoprotein (AGP) and haptoglobin (HP) were measured using previously validated assays in serum of 88 cats and effusion of 67/88 cats. Statistical analysis was performed using non-parametric tests. Diagnostic utility of parameters measured in serum and effusion was assessed by calculation of sensitivity, specificity, and accuracy, and by receiver operating characteristic analysis. Level of significance was set at pweiterlesen

Dieser Artikel gehört zu den folgenden Serien

Sprache(n): Englisch

ISBN: 978-3-8359-7159-2 / 978-3835971592 / 9783835971592

Verlag: VVB Laufersweiler Verlag

Erscheinungsdatum: 22.11.2023

Seiten: 86

Autor(en): Katarina Hazuchova

36,80 € inkl. MwSt.
kostenloser Versand

lieferbar - Lieferzeit 10-15 Werktage

zurück